SECTION 12500 DRAPERY (FINE-PLEAT HEADING SYSTEM)

PART 1--GENERAL
  1. DESCRIPTION
    1. General: Provide operable draperies in accordance with this document and plans.
    2. Related work specified elsewhere.
      1. Rough carpentry for wood blocking and support grounds.
      2. Miscellaneous metal for framing and reinforcing.
      3. Optional: Electrical power requirements and controls for motorized draperies.
  2. QUALITY ASSURANCE
    1. Provide operable draperies from a firm that has specialized in the fabrication and installation of such work for at least five (5) years in projects of similar size and scope.
    2. Provide operable draperies as complete units produced by a

 

Architectural Heading Systems Technical Information
Stacking Widths Yardage 150% of 54-in. Wide Fabric
Opening Size Fine-pleat Ripplefold & Archifold Accordia-Fold Sill (72 in.) Floor (102 in.)
32 in. 8 in. 8 in. 7 in. 5 yards 7 yards
54 11 13 12 7 1/2 10 1/2
76 14 17 1/2 17 10 14
98 16 23 22 12 1/2 17 1/2
120 19 27 1/2 27 15 21
142 22 32 32 17 1/2 24
164 25 38 38 20 28
186 28 43 43 22 1/2 31 1/2
208 31 46 48 25 35