SECTION
12500 SHADE (FESTOON [A] WITH JABOTS [B])
PART 1--GENERAL
- DESCRIPTION
- General: Provide
top treatment in accordance with this document and plans.
- Related work
specified elsewhere.
- Rough carpentry
for wood blocking and support grounds.
- Miscellaneous
metal for framing and reinforcing.
- QUALITY ASSURANCE
- Provide top
treatment from a firm that has specialized in the fabrication
and installation of such work for at least five (5) years in projects
of similar size and scope.
- Provide top
treatment as complete units produced by a single manufacturer,
including the necessary mounting brackets, hardware, fittings,
fastenings, and installation.
- Installation
shall be performed by an authorized manufacturer's representative
experienced in the installation and maintenance of such assemblies.
- STANDARDS
- Except as
modified by governing codes and contract documents, comply with
applicable provisions and recommendations of the following:
- When
required by fire codes, fabrics shall be flame resistant in
accordance with NFPA-701 test requirements.
- Flameproofing
shall leave the fabric cleanable, dimensionally stable, and
resistant to U.V. deterioration.
- SUBMITTALS
- Shop Drawings:
Submit drawings for top treatment, including dimensioned plans,
seaming instructions, details, connections, anchorages, and the
relation to adjacent construction.
- Samples:
Submit 24 x 24-in. samples of fabrics(s) as specified with cut
sheets.
- Maintenance
instructions: Submit manufacturer's printed instructions for cleaning
and maintenance of the products.
- PRODUCT DELIVERY,
STORAGE AND HANDLING
- Subcontractor
shall not deliver the top treatment until room(s) containing the
top treatment are painted and ready for installation. The top
treatment and components shall be protected from damage during
delivery and installation.
- WARRANTY
- A written
warranty agreeing to repair or replace hardware or fabric due
to faulty material, workmanship or installation for a period of
one (1) year.
PART 2--Product:
Festoon with Jabots
- MANUFACTURER
- General:
Provided a top treatment as produced by one manufacturer. Products
specified herein by proprietary designation are as manufactured
by DFB Sales, Inc., telephone (718) 729-8310, and establish the
quality standards required. Equivalent products of other manufacturers
will be considered provided they meet those established standards
and comply with the contract documents.
- FABRICATION
Specifications for festoon with jabots consist of the following:
- Festoons
(A) shall be fabricated with even, soft, graduated folds in single
or multiple units as per design drawing no.___________. Festoons
shall be unlined, lined and/or interlined. Vertical fullness shall
be _________%. If unlined, the bottom hem shall be 2 in. deep,
double-turned. If lined, the lining shall extend to the leading
edge of the hem. The top edge shall be straight and finished with
a 1-in. binding made from the face fabric. The festoon shall be
tacked or stapled to a fabric-covered wood dustboard. Fastenings
shall not be visible when completed.
- Jabots (B)
shall be fabricated with two or three even vertical, pleated folds.
The bottom of which shall be sewn on an angle creating a cascading
effect.
- A design
template with curved top and bottom edges shall be used to
maintain a uniform and aesthetically pleasing appearance.
This template shall be used to determine the size of the fabric
panel and be reversed on a paired panel in order to create
a mirror image.
- When
completed, the top edge shall be straight and finished with
a 1-in. binding made from the face fabric. The jabot shall
be attached to a wooden dustboard in front of and on top of
the festoon, swag, or draped valance that it accompanies.
- Decorative
fringe-trimming options:
- Trim
heading shall be sewn onto the bottom edge with the tassels
or fringe hanging below.
- Trim
heading shall be concealed as it is sewn into the false bottom
hem.
- Tape or braided
trimming:
- Trimming
shall be applied to the bottom edge or set back from the edge
as may be appropriate to the design.
- Trimming
shall be stitched to both edges.
- For festoons
wider than the fabric width, full widths of the fabric must be
centered on the festoon with equal widths of fabric added to each
side. No center seams are allowed.
- Hardware:
A 3/4 in.-thick fabric-covered wood board of an appropriate depth
to accommodate the under treatment without interference.
- FABRIC(S)
- Festoon fabric
selection shall be __________.
- Jabot fabric
selection shall be ____________.
- Jabot lining-fabric
selection shall be ____________.
PART 3--Execution
- EXAMINATION
- Examine substrates,
adjoining construction and conditions under which the work is
to be installed. The work shall not proceed until unsatisfactory
conditions have been corrected.
- PREPARATION
- Install festoons
with jabots and hardware in accordance with manufacturer's recommendations.
- Festoons
with jabots shall be free of creases and wrinkles after hanging
and shall be steamed and dressed down as required.
- PROTECTION:
Protect all finished work from soiling or damage after hanging.
|