SECTION 12500
SHADE (SHIRRED HEADINGS)
PART 1--GENERAL
- DESCRIPTION
- General:
Provide operable draperies in accordance with this document and
plans.
- Related work
specified elsewhere.
- Rough
carpentry for wood blocking and support grounds.
- Miscellaneous
metal for framing and reinforcing.
- QUALITY ASSURANCE
- Provide draperies
from a firm that has specialized in the fabrication and installation
of such work for at least five (5) years in projects of similar
size and scope.
- Provide draperies
as complete units produced by a single manufacturer, including
the necessary mounting brackets, hardware, fittings, fastenings,
and installation.
- Installation
shall be performed by an authorized manufacturer's representative
experienced in the installation and maintenance of such assemblies.
- STANDARDS
- Except as
modified by governing codes and contract documents, comply with
applicable provisions and recommendations of the following:
- When
required by fire codes, fabrics shall be flame resistant in
accordance with NFPA-701 test requirements.
- Flameproofing
shall leave the fabric cleanable, dimensionally stable, and
resistant to UV deterioration.
- SUBMITTALS
- Manufacturer's
Data: Submit specifications and operating and installation instructions
for draperies.
- Shop Drawings:
Submit drawings for draperies, including dimensioned plans, seaming
instructions, details, connections, anchorages, and the relation
to adjacent construction.
- Samples:
Submit 24 x 24-in. samples of fabrics(s) as specified and operable
hardware with cut sheets.
- Maintenance
instructions: Submit manufacturer's printed instructions for cleaning
and maintenance of the products.
- PRODUCT DELIVERY,
STORAGE AND HANDLING
- Subcontractor
shall not deliver the draperies until room(s) containing draperies
is (are) painted and ready for installation. Draperies and components
shall be protected from damage during delivery and installation.
- WARRANTY
- A written
warranty agreeing to repair or replace hardware or fabric due
to faulty material, workmanship or installation for a period of
one (1) year.
PART 2--Product:
Shirred Headings
- MANUFACTURER
- General:
Provided a drapery system as produced by one manufacturer. Products
specified herein by proprietary designation are as manufactured
by DFB Sales Inc., telephone (718) 729-8310, and establish the
quality standards required. Equivalent products of other manufacturers
will be considered provided they meet those established standards
and comply with the contract documents.
- FABRICATION
Specifications for shirred headings consist of the following:
- Drapery heading
shall be fabricated as follows: A top hem consisting of 2 layers
of fabric shall be sewn with either clear monofilament or triple-strand
polyester thread, color matched to the fabric used, so as to create
a pocket of an appropriate width that permits the insertion of
a _________ in. diameter pole or rod (metal or wood). A ___________
in. wide hem shall extend above the pocket.
- Drapery fullness
shall be ________%. Pocket size shall be 10% larger than 1/2 of
the circumference of the pole.
- Bottom hems
shall be double-turned 2 in. and shall consist of three layers
of fabric and blindstitched.
- If less than
a full width of fabric is required to accomplish the specified
fullness, no less than one half widths shall be used, and they
shall be located at the extreme ends of each drapery panel.
- Hardware
shall be __________ in. diameter wood or metal rod that can be
wall or ceiling mounted.
- Operation:
Heading shall be stationary.
- FABRIC(S)
- Fabric selection
shall be ___________.
PART 3--Execution
- EXAMINATION
- Examine substrates,
adjoining construction and conditions under which the work is
to be installed. The work shall not proceed until unsatisfactory
conditions have been corrected.
- PREPARATION
- Install draperies
with hardware in accordance with manufacturer's recommendations.
- Hang draperies
so that the top of the heading clears the ceiling above by 1/4
in. and the bottom hem clearance is a maximum of 1 in. from the
finished floor or 1/2 in. from the sill line.
- Draperies
shall be free of creases and wrinkles after hanging and shall
be steamed and dressed down as required.
- PROTECTION
Protect draperies from soiling or damage after hanging.
|